Welding Technical Reference

All constants, parameters, and formulas used by WeldWise to estimate filler material, shielding gas, passes, equipment, and welding time.

Welding Processes

ProcessNameBase deposition rate (kg/hr)Process efficiency
GMAWMIG (GMAW)3.595%
GTAWTIG (GTAW)1.098%
SMAWStick (SMAW)1.565%
FCAWFlux-Cored (FCAW)4.085%

The base deposition rate applies at the smallest listed electrode diameter. Diameter comparisons scale this rate for informational estimates.

Material Properties

IDMaterialDensity (g/cm³)
SteelCarbon Steel7.85
StainlessStainless Steel8.00
AluminumAluminum2.70

Calculation Formulas

Calculations use the following geometry, filler, time, gas, and pass formulas.

CalculationFormula or rule
Groove joint area (single-sided)depth² × tan(prepAngle ÷ 2) + (rootGap × depth)
Groove joint area (double-sided)side 1 area + side 2 area, calculated independently with each side's depth and angle
Fillet joint area0.5 × legSize²
Area overheadjoint area × 1.10
Back-gouge depthclamp(thickness × 0.18, min=min(3, thickness × 0.5), max=min(10, thickness))
Back-gouge area0.5 × π × gougeDepth² × (0.5 for double-sided joints; otherwise 1.0)
Back-gouging time (minutes)5 × max(0.5, thickness ÷ 10) × weldLength(m)
Volume (cm³)area(mm²) × weldLength(m) × 1000 ÷ 1000
Deposited filler weight (kg)volume × materialDensity ÷ 1000
Purchase filler weightdeposited filler weight ÷ fillerEfficiency
Arc time (hours)fillerWeight ÷ (baseDepositionRate × processEfficiency × environmentFactor × positionFactor)
Diameter-adjusted deposition ratebaseDepositionRate × (diameter ÷ referenceDiameter)
Setup time (minutes)round(arcTime × setupPercentage)
Total weld time (minutes)round((arcTime + setupTime) ÷ welderCount)
Shielding gas volume (litres)(arcTime − backGougingTime) × 15 L/min
Area per passbaseAreaPerPass × (selectedWireDiameter ÷ referenceDiameter)²
Number of passesceil(jointArea ÷ areaPerPass)

Back-gouging time is excluded from shielding-gas consumption. The selected wire diameter affects pass count; diameter-based arc-time comparisons are supplemental and do not replace the primary estimate.

Environment and Productivity Factors

FactorEnvironmentSetup time
1.0Workshop (Ideal)15% of arc time
0.8Outdoor (Exposed)50% of arc time
0.6Restricted Space75% of arc time
0.4Highly Restricted100% of arc time

Weld Position Factors

PositionNameFactor
1FFlat (1F/1G)1.00
2FHorizontal (2F/2G)0.88
3FVertical (3F/3G)0.70
4FOverhead (4F/4G)0.60

Environment and position factors multiply into the arc-time calculation; a lower factor represents slower production.

Multi-Welder Comparison

WeldersIndividual efficiencyCombined factor
1100%100%
290%180%
380%240%
470%280%
560%300%

This coordination-efficiency curve is used only in the supplemental multi-welder comparison. The primary total-time estimate divides arc time plus setup time by welder count.

Wire and Electrode Diameters

ProcessAvailable diameters (mm)Reference diameter (mm)Base area per pass (mm²)
GMAW1.2, 1.4, 1.61.240
FCAW1.2, 1.4, 1.61.250
SMAW2.5, 3.2, 4.0, 5.03.230
GTAW1.6, 2.4, 3.22.418

Filler Efficiency and Package Sizes

ProcessDefault filler efficiency
GMAW92%
GTAW98%
SMAW65%
FCAW88%
ProcessPackageWeightAllocation rule
GMAW5kg Spool5 kgMinimum one per welder
GMAW15kg Spool15 kgMinimum one per welder
GMAW250kg Drum250 kgShareable
GTAW5kg Box5 kgMinimum one per welder
GTAW10kg Box10 kgMinimum one per welder
SMAW5kg Can5 kgMinimum one per welder
SMAW20kg Can20 kgMinimum one per welder
FCAW5kg Spool5 kgMinimum one per welder
FCAW15kg Spool15 kgMinimum one per welder
FCAW250kg Drum250 kgShareable

Purchase quantity equals deposited weight divided by filler efficiency. Packages below 250 kg require at least one per welder; drums of 250 kg or more can be shared.

Shielding Gas Cylinder Sizes

ProcessCylinderVolume (L)Allocation rule
GMAWG-Size (50L)10,600Minimum one per welder
GMAWE-Size (20L)4,200Minimum one per welder
GMAWD-Size (10L)2,100Minimum one per welder
GTAWG-Size (50L)10,600Minimum one per welder
GTAWE-Size (20L)4,200Minimum one per welder
GTAWD-Size (10L)2,100Minimum one per welder
SMAWNo shielding gas required—Not applicable
FCAWG-Size (50L)10,600Minimum one per welder
FCAWE-Size (20L)4,200Minimum one per welder

Gas-shielded processes use a flow rate of 15 L/min during pure arc time. SMAW requires no shielding gas.

Equipment Requirements

EquipmentProcessesQuantity
Power sourceAll processesOne per welder
Wire feederGMAW and FCAWOne per welder

Per-welder minimum rule: required quantity = max(material-based quantity, welderCount).

Joint Types

Joint IDDescriptionClassification
Butt-VButt Joint (Single V-Groove)Groove
Butt-DVButt Joint (Double V-Groove)Groove, Double-sided
Butt-BevelButt Joint (Single Bevel)Groove
Butt-DBevelButt Joint (Double Bevel)Groove, Double-sided
Tee-BevelTee-Butt (Single Bevel)Groove
Tee-DBevelTee-Butt (Double Bevel)Groove, Double-sided
Tee-VTee-Butt (Single V-Groove)Groove
Tee-DVTee-Butt (Double V-Groove)Groove, Double-sided
FilletFillet JointFillet
LapLap JointLap

Double-sided joints accept separate preparation angles and depths for each side. Their back-gouge area is reduced by 50% because the second side is already prepared.